"another instrument with same name already exists" error with LITpro V1.1
Wednesday, April 14, 2010, 02:11 PM -
LITpro FAQPosted by JMMC User Support Team
If you encouter the error "another instrument with same name already exists", you probably have built one settings with multiple oifits files. It is actually one limitation of the internal engine which should be fixed soon. To be able to fit such settings files, you actually need to modify manually the name INSNAME keywords of each given files. It must be done in all the OI_VIS, OI_VIS2, OI_T3 plus the corresponding OI_WAVELENGTH tables. Each values must be different to be fitted by LITpro. Apologize for the actual limitation. We are working on this issue for the next releases.
An alternative is to merge multiple oifits files into a single file. This can be done using the oifitslib software available at the following address:
ftp://ftp.mrao.cam.ac.uk/pub/jsy1001/oifitslib/oifitslib.tar.gz